Mini Optimized Energy Electric Ethernet Analyzer – Amuse Tech Solutions

Compact 3-Phase Power Quality Analyzer with Modbus TCP, RJ45 Ethernet, 32GB storage, waveform recording, harmonic analysis, and rechargeable battery for energy monitoring.

SKU: ATSREA-101 Category:

Description

Overview

Amuse Tech Solutions mini optimized energy electric ethernet analyzer- three phase power quality analyzer, externally connected with open type Rogowski coil or voltage type CT, it can realize none dismantling wire test, simplify test steps, save construction cost, and is more convenient for engineering test as well as the inspection and maintenance of distribution system. Support systems of single-phase and three-phase. It can measure multiple electrical parameters such as current, voltage, power factor, power, energy, and power quality parameters including harmonic, unbalance degree, voltage swell and voltage dip, etc. In addition to the measurement function, Amuse Tech Solutions mini optimized energy electric ethernet analyzer is equipped with various records, such as waveform records and programmable interval measurement value records. To store and record data, it is an internally embedded 32 GB memory card. With standard configuration of RJ45 Ethernet communication interface, through standard Modbus TCP protocol, it is compatible with various configuration systems and could transmit the electrical parameters collected by the front end to the system data center in real time.

 

  Technical Specifications

Phase Three phases
Measuring Energy Range 0 GWh to 999.9 GWh
Output Voltage 0 VAC to 600 VAC
Display type Analog and Digital
Accuracy class Class S
Product name 3 Phase Power Quality Analyzer
Application Energy Consumption Monitoring
Communication Modbus TCP or RJ45 Ethernet
Current transformer 333 mV current clamp
Current range 0 A to 18000 A
Voltage range 0 VAC to 600 VAC
Function Graphs, Waveform, Power quality analysis
Frequency 45 Hz to 65 Hz
Type Handheld Three phase power quality analyzer
Application field Power analysis, Power measurement, Power quality analysis
Wiring system 3P4W_4CT
3P4W_3CT
3P3W_3CT
3P3W_2CT
1P2w
Current sensor Rogowski coil
Voltage output current clamp, 333 mV CTs
Voltage access Direct access
Connected through voltage transformer
Storage Type TF card
Storage Capacity 32GB
Data export U disk export (U disk file is FAT32 system)
Communication Interface RJ45 Ethernet
Communication Protocol Modbus TCP
Power Supply
Power Supply 5 VDC, 2A Adapter
Battery Rechargeable lithium battery, specification 18650, 2 pcs, capacity about 4000mAh
Battery purely working time ≥ 6h
Battery charging time (off state) ≤ 5h
Real-time measurement data
Voltage Phase voltage: Phase ABC
N phase to ground voltage
Line voltage: UAB, UBC, UCA
Voltage peak coefficient: Phase ABC
Voltage peak: Phase ABC
Current Phase current: Phase ABCN
Current peak coefficient: Phase ABC
K Factor: Phase ABC
Frequency Line frequency
Power Active power: Phase ABC and total
Reactive power: Phase ABC and total
Apparent power: Phase ABC and total
Power factor Phase ABC and total
Fundamental harmonic power factor Phase ABC and total
Electrical energy Active Energy: Phase ABC and total (import or export)
Reactive energy: Phase ABC and total (import or export)
Apparent Energy: Phase ABC and total
CO2 emissions
Harmonic measurement data
Voltage harmonics THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1st to 50th
harmonic percentage, phase ABC 1st to 50th harmonic voltage value
Current harmonics THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1st to 50th
harmonic percentage, phase ABC 1st to 50th harmonic current value
Voltage and current Waveform
Phase angle Phase ABC
Unbalance Voltage unbalance, current unbalance
Power demand and peak demand Phase ABC active power and total power, phase ABC reactive power and total power, phase ABC apparent power and total power
Current demand and peak demand Phase ABC
Voltage and Current harmonic data record Voltage and current harmonics (Total harmonic distortion THD, Odd total harmonic TOHD, even total harmonic TEHD, 1st to 50th Harmonic percentage
and voltage or current value)
Event recorded data Event type
Start time
Duration
Amplitude value
Waveform recording  Phase ABC voltage waveform and current waveform
Data storage format CSV
Operating Temperature -4 ⁰F to 131 ⁰F (-20 ℃ to 55 ℃)
Dimensions 8.46 in x 5.12 in x 2.36 in (21.5 cm x 13 cm x 6 cm)